Laparoscopy Apparatus Good Maintenance Is Particularly Important
Oct 26, 2017

Laparoscopy Apparatus, high precision, complex structure, is a collection of modern electronics, optics and mechanical and other aspects of a comprehensive system, so the daily Laparoscopy Apparatus for good maintenance is particularly important. Good maintenance is not only to extend the life of laparoscopy, reduce maintenance costs, but also reduce the incidence of intraoperative failure is an important prerequisite.

Laparoscopic surgery is a combination of several devices, only a clear understanding of the function and characteristics of each device in order to timely find the problem and solve the problem. A complete set of laparoscopic surgical equipment is usually composed of the following five parts: ① display camera system, including the display, laparoscopic lens, mirror tube, signal converter, its function is used to capture and show the body cavity clear, realistic image ; ② cold light source system, its function is to provide lighting for surgery; ③ pneumoperitoneum, its function is to provide adequate space for surgery; ④ high-frequency electric knife, including unipolar and bipolar, its function is to implement the cut target; The negative pressure suction system, including the suction tube, attracts the pipe, attracts the bottle, its function is to attract the excrement and the intraoperative flow of the tissue fluid.

(1) lavage of the laparoscopic device: the removable part of the laparoscopic device should be removed immediately and cleaned. First with the enzyme soak, and then rinse with flowing water. With the lumen of the device, after each use should be used through the brush through the brush, and then repeated washing with water or high pressure water gun. Use a cotton swab to clean the valve chamber, spring, seal and puncture cone side hole, dry after the valve in time to restore the valve to avoid the loss of small parts. Clean the gripping device and scissors should open the rotating shaft and gently scrub. If the stub is still stubborn debris is cleaned with ultrasonic cleaner. Camera, laparoscopic angle with a soft cloth to dry dry, avoid using a rough cloth towel to avoid scratching the lens, is strictly prohibited using ultrasonic cleaning machine for endoscopic cleaning.

(2) Laparoscopy Apparatus disinfection: for different devices can be used high temperature and pressure sterilization method, low temperature sterilization method for disinfection. Camera, cable and electrode can not use disinfectant soaking or high temperature autoclaving disinfection, otherwise the equipment will cause serious damage, can only use gas fumigation or plasma low temperature sterilization method.

(1) laparoscopic device placement: Laparoscopy Apparatus should be placed on the laparoscopic device, each time before and after the use of its surface to clean and covered with dust cover. The parts must be stored with a dedicated device box, equipment should be arranged in order. All sharp equipment to avoid the collision, pick and place should be light and stable. In particular, the optical system is extremely sensitive to light, the placement of equipment should be selected dark room, to avoid direct light.

(2) Laparoscopy Apparatus, regular inspection: adhere to the weekly function of the laparoscopic device to conduct a check every month for all equipment rust and lubrication maintenance 1 times.